Stormwater Attenuation Tanks | 45T Load Capacity
YD StormBreaker45®
Yude Rain Eco’s StormBreaker45® is a high-capacity, geocellular underground rainwater storage module designed for efficient stormwater attenuation, soakaway, infiltration, retention, detention, drainage or reuse.
With a load capacity of 45 tons, it is a medium option between 32T and 60T stormwater attenuation tanks for medium load environments such as parking lots, sidewalks, or public plazas where medium load performance is required.
StormBreaker45® provides a reliable and safety solution for managing surface rainwater. Whether used as a standalone system or integrated into a Sustainable Drainage System (SuDS), StormBreaker45® ensures optimal performance across diverse building applications with its robust, space-efficient design.
Key benefits
- High Storage Capacity: Up to 95% storage rate, maximizing water retention for efficient stormwater management.
- Heavy Load Capacity: Can withstand up to 45T, this model is applicable to parking lots, sidewalks, public squares, schools, or parks in urban areas, commercial areas, communities, as well as mixed residential and commercial areas, where there is a moderate amount of pedestrian and vehicle traffic.
- Durable & Long-lasting: Made from polypropylene, offering excellent corrosion resistance, UV stability, and impact resistance.
- Environmentally Friendly: Fully recyclable, supporting sustainable water management solutions.
- Customizable & Easy to Install: Modular design allows for flexible configurations and simple installation in various environments.
- Cost-effective: High performance and durability reduce long-term maintenance costs and improve system efficiency.
- Durability: Outstanding impact and abrasion resistance, with a service life of 50 years or more.
Product Name:YD StormBreaker45®
Product Size:1000*500*552(mm)/Unit
Material: Polypropylene
Product Color: Black, Blue
Product weight: 10.48kg/Unit
Load capacity: 1m³/Unit 45 Tons/㎡ (customizable)
Where are The 45T Load Capacity Required?
Medium-Traffic Parking Lots
For shopping centers and office buildings.Public Squares & Plazas
Light vehicle and pedestrian traffic areas.Pedestrian Walkways with Light Traffic
In commercial zones and parks.School Campuses
For parking lots and roads around schools.Residential & Mixed-Use Developments
Areas with both residential and commercial spaces.Hospital Campuses
For parking areas with moderate vehicle traffic.Airport Terminals
Parking areas and terminals with moderate traffic.
* Or consult Yude Rain Eco. for specific needs.
Product Specifications
Product Name & Specifications | Application Area | Advantages & Benefits | Maintenance Recommendations |
Product Name: YD StormBreaker45® | Heavy Traffic Roads & Highways | Higher Load Capacity: Supports areas with moderate to heavy traffic, offering resilience against wear. | Regular Inspection: Inspect for surface damage, check module connections and integrity. |
Product Size: 1000mm * 500mm * 552mm/unit | Industrial & Commercial Areas | Enhanced Durability: Designed for areas with high traffic and heavy equipment usage. | Clear Drainage Paths: Ensure there is no debris blocking the water flow through inlet/outlet connections. |
Material: Polypropylene | Sports Complexes & Stadiums | Long-Lasting Performance: Built for longevity even under moderate to high load conditions. | Monitor for Wear: Check for any signs of erosion or damage due to high foot traffic. |
Color: Black, Blue (Customizable) | Municipal Parking Lots & Transit Areas | Resilient Against Traffic Stress: High capacity to bear heavier loads, making it suitable for busy urban spaces. | Surface & Module Inspection: Regularly inspect for wear and tear in high-traffic areas. |
Weight: 10.48kg/unit | Large Commercial Infrastructure | Cost-Effective & Durable: Offers a balance of cost and performance for medium-load areas. | Check for Settling: Monitor for any settling of modules and ensure uniform distribution of backfill. |
Load Capacity: 45T per m² (Customizable) | Public Transport Terminals | High Storage Efficiency: Up to 95% storage capacity, providing excellent stormwater retention. | Routine Testing: Perform flow testing during heavy rain to ensure proper water management. |
|
| Eco-friendly: Fully recyclable material supports sustainable water management. | Routine Inspection Quarterly: Check for debris or compaction and ensure proper functionality. Prevent Compaction Annually: Ensure that backfill material remains uncompacted to allow proper drainage.
|
|
|
| Surface Wear Inspection Semi-Annually: Check for erosion around the surrounding soil and backfill material. Blockage Check After Heavy Rain: Ensure that water flows freely through the system by checking for blockages in the inlet/outlet areas. |
Installation steps
1. Site Preparation
Survey the Site: Conduct a site survey to assess the conditions (e.g., soil type, water table, traffic load) and determine the optimal installation location.
Excavation: Excavate the ground to the required depth and size to accommodate the modules. The trench should be wide enough to allow for proper installation and water flow.
Level the Base: Ensure the base of the trench is level and compacted to provide a stable foundation for the modules.
2. Foundation and Bedding Layer
- Install Bedding Material: Lay a bedding layer (usually crushed stone or gravel) at the bottom of the trench. This ensures proper drainage and provides support for the modules.
- Compact the Bedding: Compact the bedding material to create a firm base for the modules, ensuring a stable, uniform surface.
3. Stormwater Attenuation Tanks Placement
- Position Attenuation Tanks: Carefully place the YD StormBreaker32® attenuation tanks into the trench. Ensure that the tanks are aligned properly and the connectors (if applicable) are facing the correct direction.
- Stacking (if applicable): If stacking is required, ensure that the rainwater attenuation tanks are stacked in a stable and secure manner, following the Yude Rain Eco’s guidelines.
4. Stormwater Attenuation Tanks Connection
- Connect Stormwater Attenuation Tanks: Depending on the system design, connect the Stormwater Attenuation Tanks using interlocking mechanisms or connectors to ensure the system is secure and watertight.
- Connect to Drainage System: Link the Stormwater Attenuation Tanks to the surrounding stormwater drainage system, ensuring proper inlet and outlet connections for water flow.
5. Backfilling
- Backfill Around Tanks: Once the tanks are in place and connected, backfill the trench with appropriate material (e.g., gravel or sand) around the tanks. Avoid using materials that could cause compaction or block water flow.
- Compact the Backfill: Gently compact the backfill to ensure stability without damaging the tanks.
6. Installation of Surface Layer
- Reinforce Surface: Install a surface layer (e.g., asphalt or concrete) above the stormwater attenuation tank system, depending on the application (e.g., road, parking lot, or green space).
- Ensure Proper Drainage: Make sure that the surface layer allows for proper water drainage into the tanks. This is particularly important for areas like roads or parking lots.
7. Final Inspection & System Testing
- Inspect Alignment & Connections: Ensure all tanks are properly aligned, with secure connections and no gaps.
- Test the System: Simulate rainfall or runoff to verify water flows correctly through the tanks, checking for any leaks, blockages, or drainage issues.
8. Maintenance and Monitoring
- Establish Maintenance Schedule: Set up a regular inspection and cleaning schedule to ensure the system continues to function optimally.
- Monitor for Damage or Blockages: Check the system periodically for signs of damage or blockages and address any issues promptly.
Quality Assurance Showcase
Load Capacity Test Report & CE Certificates
FAQ
Stormwater attenuation tanks is a specially designed system used to capture, store, and manage rainwater runoff. It helps to prevent flooding by controlling how water is drained away from urban and industrial areas.
YD StormBreaker45® has a higher load capacity of 45 tons per square meter, making it ideal for heavy-duty applications like high-traffic areas, large commercial buildings, and industrial sites. It can withstand more significant loads compared to the 32T model.
Proper excavation and compacted bedding are required for all modules. For YD StormBreaker45®, extra attention should be given to the surrounding soil conditions, as the system needs to support higher load-bearing capacity.
Yes, the YD StormBreaker45® module is designed for detention, retention, and infiltration of stormwater, allowing for efficient water management and reducing the risk of flooding in developed areas.
YD StormBreaker45® is suitable for installation in areas with high traffic and heavy loads, such as:
- Urban roads and highways
- Airports and logistics centers
- Large parking lots
- Industrial zones and warehouses.
If you don't understand how much load-bearing capacity you need for your project, Yude Rain Eco offers a free consultation to advise you.
Yes, stormwater modules can be designed or adapted to meet specific requirements, such as adjusting the storage capacity, load-bearing capabilities, or installation configurations based on project needs.
Looking for a durable and high-load capacity stormwater solution?
Contact us today to discuss how YD StormBreaker45® can meet your needs!